SPECIFICATIONS
Output Voltage (each output)
|
Range:
|
0V to 32V (2V to 64V in series
mode).
|
|
Resolution:
|
10mv.
|
|
Accuracy:
|
0.05% ±10mv.
|
|
Temp. coefficient:
|
50ppm/oC (typically
20ppm/oC).
|
|
Line regulation:
|
0.001% for 10% line change
|
|
Load regulation:
|
0.005% for 50% load change
|
|
Ripple and noise:
|
Typically <1mV.
|
|
Transient response:
|
<100us to within 50mV of
setting for 50% load change.
|
|
Output impedance:
|
Typically <10mΩ
at 1kHz.
|
|
Remote Sensing:
|
Corrects for up to 0.5V of drop
per lead.
|
Output Current (each output)
|
Range:
|
1mA to 2A (1mA to 4A in parallel mode),
|
|
Resolution:
|
1mA.
|
|
Accuracy:
|
0.1% ±1mA.
|
|
Temp. coefficient:
|
<75ppm/oC (typically 40ppm/oC).
|
|
Ripple and noise:
|
Typically <0.2mA.
|
|
Output impedance:
|
Typically 50kΩ
with voltage limit at max.
|
Output Mode
Each output can operate in constant voltage or
constant current mode with automatic crossover. A display annunciator (flashing
delta sign) indicates constant current mode.
Output Configuration
|
Isolated:
|
Two independently set isolated
supplies (0 to 32V. 1mA - 2A).
|
|
Isolated tracking:
|
Two isolated supplies as above,
voltage settings track.
|
|
Series:
|
Higher voltage output (2V to
64V, 1mA to 2A).
|
|
Parallel:
|
Higher current output (0V to
32V, 1mA to 4A).
|
|
Isolation:
|
±300V DC max.
|
Voltmeter (each output)
|
Resolution:
|
10mV.
|
|
Accuracy:
|
±(0.05% of reading + 10mV).
|
Current Meter (each output)
|
Resolution:
|
1mA.
|
|
Accuracy:
|
±(0.1% of reading + 1mA).
|
Over-voltage Protection (each output)
|
Range:
|
1V to 35V (3.2V to 70V in series
mode).
|
|
Resolution:
|
0.2V,
|
|
Accuracy:
|
±(2% +0.2V).
|
Output Protection (each output)
|
Forward Voltage:
|
Inherently protected up to OVP
setting. Output trips off above OVP setting (70V max.)
|
|
Reverse Voltage:
|
Diode clamped (0.7V) for reverse
voltages. Max. reverse current 3A continuous.
|
Output Terminals
|
Front panel:
|
4mm terminals on 19mm
(0.75") spacing.
|
|
Rear panel:
|
Screw terminals for output and
sense.
|
Output On/Off
Independent switches for each output isolate the
terminals and allow voltage and current limits to be set before connecting to
load. Master on/off connects/isolates both outputs simultaneously
Non-Volatile Memory
25 memory locations are provided, Each location
can store the full instrument set-up including voltage, current, OVP, output
configuration etc. The power down settings are also stored and are restored when
the unit is turned back on.
GPIB Response Times
|
Interface:
|
<15ms (single command,
buffer empty).
|
|
Output TSP3222:
|
Up - <5ms for a 10V step.
Down - <5ms for a 10V step at full load, <200ms for a 10V step at
zero load.
|
|
Output TSP3222H:
|
Up - <5ms for a 10V step.
Down - <5ms for a 10V step at any load.
|
Note that the total response time to a GPIB
command is the sum of the interface and output response times.
GPIB Implementation (conforms to IEEE-488.1 and IEEE-488.2)
|
Multiline commands:
|
DCL, LLO, SDC, GTL, UNT, UNL,
SPE, SPD, PPU,PPC
|
|
Interface functions:
|
SH1, AH1, T6, L4, SR1, RL1, PP1,
DC1, DT0, C0, E2
|
|
Programmable params.:
|
Set volts, set current, set OVP,
set output on/off, set master on/off, set mode (series/parallel etc.), set
meter damping, store/recall instrument settings, read back set volts/set
current/set OVP/output volts/output current, up/down load learn string,
up/down load all stores, set SRQ response, configure parallel poll
response, execute self-test.
|
|
SRQ modes:
|
Event registers and SRQ mask as
defined by IEEE-488.2
|
|
SRQ available on:
|
Command error, execution error,
time-out error, query error, OPC, change of output mode CV to Cl or Cl to
CV, MAV, FAULT.
|
|
PP configurations:
|
ist, bit position and sense of
response bit.
|
Power Requirements
|
Input voltage:
|
Internally set for 110V, 120V,
220V, 230V or 240V ±10%, user resettable.
|
|
Power consumption:
|
300VA max.
|
Environmental & Safety
|
Electrical safety:
|
Complies with EN61010-1
|
|
EMC:
|
Complies with EN50081-1 and
EN50082-1
|
|
Operating range:
|
5oC to 40oC, 20% to 80% RH.
Thermal trips for each output to protect against over temperature.
|
|
Storage range:
|
-20oC to +60oC.
|
Mechanical Details
|
Size:
|
210mm x 129 mm x 380mm (W x H x
D)
|
|
Weight:
|
11 kg.
|
|